NextGenpack
Back to Product Tests
Humidity Exposure Test
Scope The objective of this standard is to maintain uniform test procedure to evaluate the resistance of the specimen to humidity
Reference ASTM D7444 - 11
Test Procedure
  • Fix the test specimen on test fixture, so that the degrees of freedom of the assembly are firmly constrained.
  • The specimen should be kept in Humidity chamber.
  • Set to a temperature of 40 ±2°C and a relative humidity of 93 ± 2%
  • The specimen is kept at this condition for 168hrs.
Description of image
Evaluation After the test the test specimen should undergo stacking test as per WATER/GDC/T005.
Check for physical deterioration of the CLD.
Level of Acceptance / Success Criteria Parts should undergo WATER/GDC/T004 & WATER/GDC/T005 and to be evaluated.
All Test specimens should pass the test.